Voltage | 0V~5V |
Current | Single channel: 0-300A, channel parallel: -600A |
aisle | 1-24 channels optional |
Voltage accuracy | ±0.05%FS |
Current accuracy | 0.05%SV |
Current settling time | 2ms or less |
Charge and discharge switching time | Below 4ms |
Inspection time | 100ms minimum |
Data sampling time | 1ms minimum |
Support process type | CC, CC/CV, CP, CR |
safety protection | OVP, UVP, OCP, OTP, EMG, etc. |
Equipment size | 800*1200*1950 (5V, 300A, 16 channels) |
Peripherals | Temperature, voltage DAQ (expandable 128 channels) |
1. This machine is suitable for automatic DCIR testing of cylindrical batteries; 2. Connecting to the logistics line, the entire pallet is automatically loaded and scanned; 3. DCIR is automatically completed for the entire plate, which is fast and reliable; 4. Automatically unloading
Cylindrical battery sorting machine1. This machine is suitable for automatic OCV testing/sorting of cylindrical batteries; 2. Docking the logistics line, automatically loading the entire pallet and scanning codes; 3. OCV completes the test automatically, fast and reliable; 4. Automatically completes the production data information Binding, automatic sorting; 5. Sorting level: 10+1; 6. Automatic blanking;
Contact address: No. 2 Taihe Road, Hengli Village, Wangniudun Town, Dongguan (in the courtyard of Guohong Building)
Contact: Jun Fang
email:steve@lai-tech.com.cn
Contact information:+6582605806
Online message