①: High TemperatureStanding |
②: Thermal pressure Formation |
③: OCV Testing |
④: Disassembler |
⑤: Degass |
⑥: Trayfiller |
⑦: Side voltage test |
⑧: Re-sealing Machine |
⑨: Normal TemperatureStanding |
⑩: Capacity Grading |
⑪: DCIR Testing DCIR Testing |
⑫: Sorting |
Soft pack battery charging and discharging equipment
type of battery |
Soft pack battery |
Current |
20A, 60A, 100A, 150A, 200A |
Circuit type |
Energy feedback type |
Features of soft pack battery charging equipment
Temperature uniformity |
±1.5℃ |
Safety inspection |
Six-wire collection |
Voltage accuracy |
1mv |
Current accuracy |
0.05%FS |
Power modular design |
|
Constant voltage discharge function |
|
Channel parallel function |
Soft package thermocompression forming equipment
Sorting equipment
Power specifications and main parameters
System specifications |
5V3A |
5V5A |
5V10A |
5V12A |
5V20A |
5V40A |
5V60A |
5V120A |
5V200A |
5V1000A |
Number of channels |
128 |
64 |
twenty four |
16 |
12 |
8 |
8 |
4 |
2 |
1 |
Voltage accuracy |
±1mV (OCV: ±1mV) |
|||||||||
Current accuracy |
±0.05% FS |
|||||||||
Channel characteristics |
The discharge energy is fed back to the grid, which saves more than 70% energy compared to conventional equipment; the constant current source and the constant voltage source adopt a single-loop structure: current and voltage error automatic calibration technology; firmware remote automatic online upgrade; standard modular design to meet mass production; |
|||||||||
Module terminal discharge input voltage range |
1800mV-5000mV |
|||||||||
Charging mode |
Constant current charging, constant voltage charging, constant current and constant voltage charging |
|||||||||
Single module (port) discharge efficiency |
≥80% |
|||||||||
Charging cut-off condition |
Voltage, current, time, capacity, temperature |
|||||||||
Discharge mode |
Constant current discharge, constant voltage discharge |
|||||||||
Discharge cut-off condition |
Voltage, current, time, capacity |
|||||||||
Safety monitoring function |
Six-wire collection |
|||||||||
Optional function |
Channel parallel function, DC internal resistance test function |